Please use this identifier to cite or link to this item: http://ricaxcan.uaz.edu.mx/jspui/handle/20.500.11845/715
Title: Passive neutron area monitor with CR39
Authors: Vega Carrillo, Héctor René
Barquero, Raquel
Mercado Sánchez, Gema Alejandrina
Issue Date: Jul-2013
Publisher: Novin Medical Radiation Institute
Abstract: In high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with ac ve detectors is useless; in these condi ons neutron measuring devices must have a passive detector. Here a passive neutron area monitor with CR39 track detector was designed and the response was calculated. Materials and Methods: The response of a passive neutron area monitor with CR39 track detector has been calculated with the MCNPX code. To increase the detec on efficiency a 10B converter was included. The response was calculated using 47 monoenerge c neutron sources. Results: A passive neutron area monitor using a CR39 with 10B converter was designed where fluence and H*(10) responses were calculated. Conclusion: The shape of the responses is similar to responses reported for neutron monitors with ac ve detectors.