Please use this identifier to cite or link to this item:
http://ricaxcan.uaz.edu.mx/jspui/handle/20.500.11845/737
Title: | Neutron area monitor with passive detector |
Authors: | Valero Luna, Claudia Guzmán García, Karen Arlete Borja Hernández, Candy Gretel Hernández Dávila, Víctor Martín Vega Carrillo, Héctor René |
Issue Date: | Jun-2012 |
Publisher: | Sociedad Mexicana de Física, A.C. Departamento de Física, 2o. Piso, Facultad de Ciencias, UN |
Abstract: | Se utilizó el método de Monte Carlo para calcular las respuestas de un monitor de neutrones pasivo. Para detectar los neutrones térmicos el monitor tiene una l´amina de oro que se encuentra en el centro de un cilindro de polietileno. Los neutrones que inciden son moderados por los núcleos de polietileno que llega a la l´amina de oro con la energía para inducir la activación a través de la 197Au reacción (n, °) 198Au. El 197Au decae emitiendo rayos gamma de 0.411 MeV con una vida media de 2.7 días. La actividad inducida se destina a medir con un espectrómetro de rayos gamma con un detector de centelleo de 3” £ 3” NaI (Tl) y la actividad de saturación se correlaciona con la dosis equivalente ambiental. La respuesta se calculó para 47 fuentes de neutrones monoenergéticos desde 1£10¡9 a 20 MeV. La respuesta a la fluencia se comparó con la respuesta del monitor de ´area LB 6411. |
Description: | Using Monte Carlo methods the responses of a passive neutron monitor area has been calculated. To detect thermal neutrons the monitor has a gold foil that is located at the center of a polyethylene cylinder. Impinging neutrons are moderated by polyethylene nuclei reaching the gold foil with the energy to induce activation through the reaction 197Au(n, °) 198Au. The 198Au decays emitting 0.411 MeV gamma rays with a half life of 2.7 days. The induced activity is intended to be measured with a gamma-ray spectrometer with a 3” £ 3” NaI(Tl) scintillator and the saturation activity is correlated to the ambient dose equivalent. The response was calculated for 47 monoenergetic neutron sources ranging from 1£10¡9 to 20 MeV. Calculated fluence response was compared with the response of neutron monitor area LB 6411. |
URI: | http://localhost/xmlui/handle/20.500.11845/737 https://doi.org/10.48779/1p7g-0016 |
ISSN: | 0035-001X |
Other Identifiers: | info:eu-repo/semantics/publishedVersion |
Appears in Collections: | *Documentos Académicos*-- UA Ciencias Nucleares |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Neutron area monitor.pdf | 291,18 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License