Title: | Neutron Dosimetry in Solid Water Phantom |
Authors: | Benites Rengifo, Jorge Luís Vega Carrillo, Héctor René |
Issue Date: | 2014 |
Publisher: | AIP Publishing |
Abstract: | The neutron spectra, the Kerma and the absorbed dose due to neutrons were estimated along the incoming beam in a solid water phantom. Calculations were carried out with the MCNP5 code, where the bunker, the phantom and the model of the15 MV LINAC head were modeled. As the incoming beam goes into the phantom the neutron spectrum is modified and the dosimetric values are reduced. |
URI: | http://localhost/xmlui/handle/20.500.11845/756 https://doi.org/10.48779/jcwv-ef07 |
Other Identifiers: | info:eu-repo/semantics/publishedVersion |
Appears in Collections: | *Documentos Académicos*-- UA Ciencias Nucleares |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Neutron dosimetry in solid water.pdf | 810,51 kB | Adobe PDF | View/Open |