Please use this identifier to cite or link to this item: http://ricaxcan.uaz.edu.mx/jspui/handle/20.500.11845/770
Full metadata record
DC FieldValueLanguage
dc.contributor6207es_ES
dc.contributor.otherhttps://orcid.org/0000-0002-7081-9084es_ES
dc.coverage.spatialGlobales_ES
dc.creatorVega Carrillo, Héctor René-
dc.creatorManzanares Acuña, Eduardo-
dc.creatorHernández Dávila, Víctor Martín-
dc.creatorArcos Pichardo, Arelí-
dc.creatorBaquero, Raquel-
dc.creatorIñiguez de la Torre, María Pilar-
dc.date.accessioned2019-03-15T15:00:55Z-
dc.date.available2019-03-15T15:00:55Z-
dc.date.issued2006-10-
dc.identifierinfo:eu-repo/semantics/publishedVersiones_ES
dc.identifier.issn0094-243Xes_ES
dc.identifier.issn1551-7616es_ES
dc.identifier.urihttp://localhost/xmlui/handle/20.500.11845/770-
dc.identifier.urihttps://doi.org/10.48779/nb3e-ka43es_ES
dc.description.abstractThe use of 131I is widely used in diagnostic and treatment of patients. If the patient is pregnant the 131I presence in the thyroid it becomes a source of constant exposition to other organs and the fetus. In this study the absorbed dose in the uterus of a 3 months pregnant woman with 131I in her thyroid gland has been calculated. The dose was determined using Monte Carlo methods in which a detailed model of the woman has been developed. The dose was also calculated using a simple procedure that was refined including the photons´ attenuation in the woman organs and body. To verify these results an experiment was carried out using a neck phantom with 131I. Comparing the results it was found that the simple calculation tend to overestimate the absorbed dose, by doing the corrections due to body and organs photon attenuation the dose is 0.14 times the Monte Carlo estimation.es_ES
dc.language.isoenges_ES
dc.publisherAIP Publishinges_ES
dc.relationhttps://aip.scitation.org/doi/abs/10.1063/1.2356404es_ES
dc.relation.urigeneralPublices_ES
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceMedical Physics, Ninth Mexican Symposium on Medica Physics, AIP Conference Proceedings, Vol. 854, No. 1, octubre 2006es_ES
dc.subject.classificationMEDICINA Y CIENCIAS DE LA SALUD [3]es_ES
dc.subject.otherMonte Carloes_ES
dc.subject.otherDosimetryes_ES
dc.subject.otherThyroid glandes_ES
dc.titleAbsorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131Ies_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
Appears in Collections:*Documentos Académicos*-- UA Ciencias Nucleares

Files in This Item:
File Description SizeFormat 
Absorbed dose2.pdf787,64 kBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons