Please use this identifier to cite or link to this item: http://ricaxcan.uaz.edu.mx/jspui/handle/20.500.11845/785
Full metadata record
DC FieldValueLanguage
dc.contributor6207es_ES
dc.contributor.otherhttps://orcid.org/0000-0002-7081-9084es_ES
dc.coverage.spatialGlobales_ES
dc.creatorVega Carrillo, Héctor René-
dc.creatorBenites Rengifo, Jorge Luís-
dc.creatorHernández Dávila, Víctor Martín-
dc.creatorOrtíz Rodríguez, José Manuel-
dc.creatorde León Martínez, Héctor Asael-
dc.date.accessioned2019-03-15T16:31:12Z-
dc.date.available2019-03-15T16:31:12Z-
dc.date.issued2016-08-
dc.identifierinfo:eu-repo/semantics/publishedVersiones_ES
dc.identifier.issn2321-8649es_ES
dc.identifier.issn2321-9289es_ES
dc.identifier.urihttp://localhost/xmlui/handle/20.500.11845/785-
dc.identifier.urihttps://doi.org/10.48779/cysr-0875es_ES
dc.description.abstractThe response functions of a NaI(Tl) detectors have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. Calculated responses were used to estimate the detector efficiency for pointlike and distributed sources. Samples of cylindrical Portland cement were prepared and exposed to the photoneutron field produced by a 15 MV linac used for radiotherapy. Short half-life radioisotopes were induced and the activity was determined by measuring the pulse-height spectra with a NaI(Tl) g-ray spectrometer that was calibrated using point-like sources. Instead of doing corrections due to differences between the geometry, material and solid angle of point-like sources used for calibration, and the Portland cement cylinders, the detection efficiency was determined using the ratio between the efficiencies for the point-like and the distributed sources estimated with the Monte Carlo calculations, and the activity of the induced isotopes in cement was obtained.es_ES
dc.language.isoenges_ES
dc.publisherChitkara Universityes_ES
dc.relation.urigeneralPublices_ES
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceJournal of Nuclear Physics, Material Sciences, Radiation and Applications, Vol. 4, No. 1, agosto 2016, pp. 129–137es_ES
dc.subject.classificationCIENCIAS FISICO MATEMATICAS Y CIENCIAS DE LA TIERRA [1]es_ES
dc.subject.otherGamma- rayes_ES
dc.subject.otherPoint-like sourcees_ES
dc.subject.otherDistributed sourcees_ES
dc.subject.otherNaI(Tl) responsees_ES
dc.subject.otherMonte Carloes_ES
dc.titleNaI(Tl) Scintillator's Response Functions for Point-like and Distributed Gamma-ray Sourceses_ES