Please use this identifier to cite or link to this item:
http://ricaxcan.uaz.edu.mx/jspui/handle/20.500.11845/728
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor | 6207 | es_ES |
dc.contributor.other | https://orcid.org/0000-0002-7081-9084 | es_ES |
dc.coverage.spatial | Global | es_ES |
dc.creator | Guzmán García, Karen Arlete | - |
dc.creator | Gallego Díaz, Eduardo | - |
dc.creator | Lorente, Alfredo | - |
dc.creator | Borja Hernández, Candy Gretel | - |
dc.creator | Valero Luna, Claudia | - |
dc.creator | Hernández Dávila, Víctor Martín | - |
dc.creator | Vega Carrillo, Héctor René | - |
dc.date.accessioned | 2019-03-13T18:09:32Z | - |
dc.date.available | 2019-03-13T18:09:32Z | - |
dc.date.issued | 2011-09 | - |
dc.identifier | info:eu-repo/semantics/publishedVersion | es_ES |
dc.identifier.uri | http://localhost/xmlui/handle/20.500.11845/728 | - |
dc.identifier.uri | https://doi.org/10.48779/y09x-zj20 | es_ES |
dc.description.abstract | The response of a passive neutron monitor area has been calculated using the Monte Carlo code MCNP5. The response was the amount of n(6Li, T) reactions occurring in a TLD600 located at the center of a cylindrical polyethylene moderator. Fluence, (n, a) and H*(10) responses were calculated for 47 monoenergetic neutron sources. The H*(10) relative response was compared with responses of commercially available neutron monitors being alike. Due to 6Li cross section (n, ) reactions are mainly produced by thermal neutrons, however TLD600 is sensitive to gamma-rays; to eliminate the signal due to photons monitor area was built to hold 2 pairs of TLD600 and 2 pairs of TLD700, thus from the difference between TLD600 and TLD700 readouts the net signal due to neutrons is obtained. The monitor area was calibrated at the Universidad Politecnica de Madrid using a 241AmBe neutron source; net TLD readout was compared with the H*(10) measured with a Berthold LB6411. Performance of the neutron monitor area was determined through two independent experiments, in both cases the H*(10) was statistically equal to H*(10) measured with a Berthold LB6411. Neutron monitor area with TLDs pairs can be used in working areas with intense, mixed and pulsed radiation fields. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Sociedad Mexicana de Irradiación y Dosimetría | es_ES |
dc.publisher | Universidad Autónoma Metropolitana | es_ES |
dc.relation.uri | generalPublic | es_ES |
dc.rights | Atribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
dc.source | XII International Symposium/XXII National Congress on Solid State Dosimetry | es_ES |
dc.subject.classification | CIENCIAS FISICO MATEMATICAS Y CIENCIAS DE LA TIERRA [1] | es_ES |
dc.subject.other | passive neutron monitor | es_ES |
dc.subject.other | thermal neutrons | es_ES |
dc.subject.other | AmBe neutron source | es_ES |
dc.title | Response of a neutron monitor area with TLDs pairs | es_ES |
dc.type | info:eu-repo/semantics/conferenceObject | es_ES |
Appears in Collections: | *Documentos Académicos*-- UA Ciencias Nucleares |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Response of a neutron monitor.pdf | 732,58 kB | Adobe PDF | View/Open |
This item is licensed under a Creative Commons License