Please use this identifier to cite or link to this item: http://ricaxcan.uaz.edu.mx/jspui/handle/20.500.11845/728
Full metadata record
DC FieldValueLanguage
dc.contributor6207es_ES
dc.contributor.otherhttps://orcid.org/0000-0002-7081-9084es_ES
dc.coverage.spatialGlobales_ES
dc.creatorGuzmán García, Karen Arlete-
dc.creatorGallego Díaz, Eduardo-
dc.creatorLorente, Alfredo-
dc.creatorBorja Hernández, Candy Gretel-
dc.creatorValero Luna, Claudia-
dc.creatorHernández Dávila, Víctor Martín-
dc.creatorVega Carrillo, Héctor René-
dc.date.accessioned2019-03-13T18:09:32Z-
dc.date.available2019-03-13T18:09:32Z-
dc.date.issued2011-09-
dc.identifierinfo:eu-repo/semantics/publishedVersiones_ES
dc.identifier.urihttp://localhost/xmlui/handle/20.500.11845/728-
dc.identifier.urihttps://doi.org/10.48779/y09x-zj20es_ES
dc.description.abstractThe response of a passive neutron monitor area has been calculated using the Monte Carlo code MCNP5. The response was the amount of n(6Li, T) reactions occurring in a TLD600 located at the center of a cylindrical polyethylene moderator. Fluence, (n, a) and H*(10) responses were calculated for 47 monoenergetic neutron sources. The H*(10) relative response was compared with responses of commercially available neutron monitors being alike. Due to 6Li cross section (n, ) reactions are mainly produced by thermal neutrons, however TLD600 is sensitive to gamma-rays; to eliminate the signal due to photons monitor area was built to hold 2 pairs of TLD600 and 2 pairs of TLD700, thus from the difference between TLD600 and TLD700 readouts the net signal due to neutrons is obtained. The monitor area was calibrated at the Universidad Politecnica de Madrid using a 241AmBe neutron source; net TLD readout was compared with the H*(10) measured with a Berthold LB6411. Performance of the neutron monitor area was determined through two independent experiments, in both cases the H*(10) was statistically equal to H*(10) measured with a Berthold LB6411. Neutron monitor area with TLDs pairs can be used in working areas with intense, mixed and pulsed radiation fields.es_ES
dc.language.isoenges_ES
dc.publisherSociedad Mexicana de Irradiación y Dosimetríaes_ES
dc.publisherUniversidad Autónoma Metropolitanaes_ES
dc.relation.urigeneralPublices_ES
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.sourceXII International Symposium/XXII National Congress on Solid State Dosimetryes_ES
dc.subject.classificationCIENCIAS FISICO MATEMATICAS Y CIENCIAS DE LA TIERRA [1]es_ES
dc.subject.otherpassive neutron monitores_ES
dc.subject.otherthermal neutronses_ES
dc.subject.otherAmBe neutron sourcees_ES
dc.titleResponse of a neutron monitor area with TLDs pairses_ES
dc.typeinfo:eu-repo/semantics/conferenceObjectes_ES
Appears in Collections:*Documentos Académicos*-- UA Ciencias Nucleares

Files in This Item:
File Description SizeFormat 
Response of a neutron monitor.pdf732,58 kBAdobe PDFThumbnail
View/Open


This item is licensed under a Creative Commons License Creative Commons